Description
The Master III (1P/1P) Series UPS systems are designed to deliver high power output using identical power modules inside the unit.

At a glance
True double-conversion
DSP Control
Input power factor correction
RS-232/EPO/USB communication
SNMP communication (Optional)
Output Power Factor 1.0
True Online Double Conversion Technology
A true online double-conversion UPS ensures a constant, clean, and reliable power supply for critical operations.
By eliminating power fluctuations and outages, it safeguards equipment, minimises downtime, and protects against costly disruptions.

Emergency Power Off Function
Safety feature that will immediately disconnect the UPS loads from utility power in the event of an emergency to ensure there’s no risk of electrical shock when fire extinguishers or sprinklers are set off inside the room.

Outstanding Energy Efficiency
High >0.99 power factor and <4% harmonics boost efficiency, cut energy loss, and lower costs.
Up to 95% full-load efficiency reduces energy use and cuts operating costs.

3-Stage Charger
Service life of the batteries increases as 3-stage charging prevents overcharging.

-
Touch Screen LCD
Touch screen LCD & LED dual display for easy, comprehensive control.

Alarm Protection
Built-in self-diagnostics catch issues early, ensuring safe and reliable performance.
Tech Specs
MODEL
PRO806-III-QS Phase 1 phase in / 1 phase ou Capacity 6000 VA / 6000 W Parallel Capability 3 Output Power Factor 1 Design Topology Online True Double Conversion INPUT Nominal Voltage 200/208/220/230/240 VAC Voltage Ranga 110~300VAC ± 3 % at 60% load ; 176~300VAC ± 3 % at 100% load Frequency Range 46~54 Hz or 56~64 Hz 40 ~ 70 Hz (In generator mode) Power Factor ≧ 0.99 @ full load THDi < 4% @100% R load Input Circuit Breaker 50~63A OUTPUT Output Voltage 208*/220/230/240 VAC AC Voltage Regulation (Batt. Mode) 41% Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz Frequency Range (Batt. Mode) 50 Hz + 0.1 Hz or 60 Hz + 0.1 Hz Current Crest Ratio 3:1 (max.) Harmonic Distortion =1% THD (Linear Load) ; = 4 % THD (Non-linear Load) Transfer AC Mode to Batt. Mode
Time Inverter to ByoassZero
ZeroLeakage Current ≤ 2 mA Waveform (Batt. Mode) Pure Sinewave Overload AC Mode
Battery Mode100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately switch to bypass
100%~110%: 3min, 110%~130%: 30S, >130% : immediatelyEFFICIENCY AC Mode 95% ECO Mode 97% @ battery fully charged Battery Mode 93% BATTERY Standard Model Battery Type 12 V / 9 Ah Numbers 16 Typical Recharge Time 4-7 hours recover to 90% capacity Charging Current (max.) 1A/2A ± 10% (Default) Charging Voltage 218.4 VDC ± 1% Temperature Compensation Charging YES Long- run Model Battery Type Sealed, lead-acid battery Numbers 16–20** Charging Current (max.) 2A ± 10% (Default) 1A/2A/4A/6A/8A adjustable Charging Voltage (13.65VDC x battery number) ± 1% Temperature Compensation Charging N/A INDICATORS LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions PHYSICAL Standard Model Dimension, D x W x H (mm)
Net Weight (kgs)369 x 190 x 688 55