KSTAR MP 6k S Smart on-line UPS, Tower, 6KVA / 5.4KW Single Phase

59,000.00

Category: Tags: , , , , , , , , , ,

Description

MEMOPOWER-Ⅲ Series

1:1 Phase PF 0.9 (

Power range:6kVA~10kVA

 

中小功率UPS全系列 1-20kva 28P骑马钉

Kstar MP 10k S 10KVA / 900W Online double conversion Single Phase – XBSAsia I.T. Solutions

 

Features
·Online double conversion with full digital control
·Optimization battery group, the quantity of battery:
16/18/20pcs (Settable)
·Wide input voltage range:110~286Vac
·Input power factor 0.99 with PFC
·Wide input frequency range
·Selectable output voltage: 208/220/230/240Vac
·Generator compatible
·ECO mode operation for energy saving
·Self-testing when UPS startup
·Multiple communication interface:RS232/USB/EPO(Dry contact
/SNMP card optional)
·Cold start
·Design with maintenance switch (Optional)
·Intelligent fan speed regulation
·Multiple protection function:short-circuit,overload,overheat, battery
overcharge and overdischarge,output low voltage and fan fault alarm

 

TECH SPECS

 

Technical Specifications:

MODEL MP 6k S
Capacity 6000VA/ 5400W

INPUT
Nominal voltage 208/220/230/240Vac
Input voltage range 110~286Vac
Frequency range 40~70Hz (50/60Hz Auto-Sensing)
Power factor ≥0.99
Bypass voltage range Max.voltage:230~264Vac
Min.voltage:176~220Vac

OUTPUT
Output voltage 208/220/230/240Vac
Power factor 0.9
Voltage regulation ±1%
Output frequency
Line Mode ±10% of the rated frequency
Bat. Mode (50/60±0.1%)Hz
Crest factor 3:1
Harmonic distortion (THDv ≤2% Linear load
≤5% Non linear load

Transfer time
AC mode to Bat.Mode 5ms (Typical)
Inverter to Bypass Pure Sinewave

Overload
Line Mode Load≤105% long time running; ≤125% last 10min; ≤130% last 30s; >130% turn to bypass mode immediately
Bypass Mode 40A (Breaker)
Efficiency 93.5%

BATTERY
Battery voltage 192/216/240Vdc (Adjustable) ,without neutral
Capacity (Standard unit) 9Ah/12V (7Ah/12V optional)
Typical recharging time 6~8 hours (to 90% of full capacity)
Charging current 1A (Standard unit); Long run unit Max.current 8A (Charging current can be set according to battery capacity)

INDICATORS
LED display Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD display Input voltage,Input frequency,Output voltage,Output frequency,Load percentage,
Battery voltage,Inner temperature& Remaining battery backup time

ALARM
Battery mode Beeping every 4 seconds
Battery low Beeping every second
Overload Beeping twice every second
Fault Continously beeping

PHYSICAL
Dimension W x D×H (mm) H:191 x 460 x 337;S:191 x 460 x 720 (With wheel)
Net weight (kg) 69.5

ENVIRONMENT
Operating temperature 0℃~40℃
Storage temperature 0~40℃ (Non condensing) -25℃~55℃
Humidity range 20~95%RH @ 0~40℃ (Non condensing)
Altitude <1500m,derating required when>1500m
Noise level <55dB at 1 Meter

STANDARDS
Safety IEC/EN62040-1,IEC/EN62477-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8

 

Reviews