ABLEREX MS II RT 15KVA 13KW Single phase Double Online conversion UPS

210,000.00

Description

The Ablerex MSII-RT Parallel Redundancy On-Line UPS, is the perfect solution for mission critical users who demand high reliability, availability and performance for critical electronic equipment and computer loads.
It features double conversion True Online Technology, field-proven full Digital Signal Processor (DSP) and utilises our uniquely patented inverter control technology. The Ablerex MSII Parallel On-Line UPS is a scalable system which achieves N + 1 redundancy without any additional parts.

Simple Parallel Installation (No extra PCB require)
Install for operation in parallel to increase power capacity or make redundant system. Simply connect the parallel control lines through the RJ-45 connector on the rear panel with CAM-bus and communication is established to all units. The maximum parallel operation configuration is 4 units.

Full Digital Signal Processor (DSP) Control

Provides both pure sine waves at the output and perfect sine waves to the input current to ensure compatibility with all kinds of loads. Full DSP technology also allow:

Programmable Frequency Converter
Reprogram the UPS to be a Frequency Converter for either 50Hz or 60Hz through front keypad configuration.

 

Easy-to-Set User Personalization
Through the LCD front panel, you can easily change the built-in parameters and settings of the DSP controllers, such as UPS operation modes voltage configurations, synchronization frequency windows, bypass voltage tolerance and buzzer alarm status.

 

Mars II RT 3/1 - Single Phase Online UPS - Products

Ablerex MSII10000RT 10KVA / 9000W Online Double Conversion (Rack / Tower

• Intelligent Self-Diagnostics
Through the self-diagnostics inside the DSP, system faults can be pin-pointed rapidly which results in faster repair times easier servicing. Simply access the service mode and check each device step by step, through the results displayed on the LCD display.

• Smart Fan Control
The speed of the internally mounted cooling fans are controlled according to load percentage to reduce noise levels and energy consumption.

True Double Conversion On-Line Technology
Corrects power disturbances from the utility power and regenerates clean and safe AC power. The Voltage Frequency Independent [VFI] working mode of the UPS complies with EN60240-3 ,European Directives for True-On-Line Technology.

High Input Power Factor and Low Current THD
Provides a clean rectifier connection to the utility power. It meets today’s industry standards for energy saving and low current harmonic pollution to the utility power and achieves up to 0.99 at Input Power Factor as well as <5% Current THO.

Energy-efficient UPS
The AC to AC efficiency of the UPS reaches up to 90% at 50% load and better at larger loadings. Using the ECO mode, efficiencies of up to 97% can be achieved.

 

STANDARD SPECS 

Model MSll 15000RT (V)
INPUT
190-486Vac (3P/1P)
Frequency 45~ 70 Hz
Phase /Wire Three +G
Power Factor 3P/1P Uplo95% at 100% Linear Load
Current THD 3P/1P <30% at 100% Linear Load

OUTPUT
Voltage 200/208/220/230/240Vac
Voltage Adjustment Nominal+ 1 %, +2%, +3%, -1 %, -2% or -3%
Voltage Regulation 15000VA/ 13500W
Rated Power Factor 0.9 lagging
Wave From Sine wave I Voll age THO <1 % (max with linear load)

Frequency Regulation 50/GOHz ± 1 Hz or± 3Hz (Selectable)
Transfer Time 0msec
Crest Factor 3: 1 acceptable
Efficiency (AC to AC, Normal! Up to 90%
Efficiency (AC to AC, ECO) Up to 95%
Autonomy (run time at full load) -5-30 mins depending on Load
DC Start Yes

BATTERY
Type Sealed Lead Acid Maintenance Free
Capacity 9AH
Quantity 16pcs or 20pcs
Voltage 92Vac or 240Vac
Recharge Time 4 Hours to 90%

DISPLAY
Status on LED + LCD Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnect, Overload, Transferring with Interruption, & UPS Fault

Readings on LCD Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature.

Self-Diagnostics Upon Power-on & Front Panel Setting

PROTECTION
Overload
(with simulated thermal tripping I-T curve)

AC Mode:
– 121%-150% for 10 sec
-150% immediately
Bypass Mode: – 146% -148% for 5 sec shutdown
-149% -155 for 2 sec shut down
>158% -176% for 1 sec shut down
>177% -187% for 0.32 sec shutdown

Short Circuit Inverter Switch Off Immediately
Overheat AC mode : Switch to Bypass
Backup mode: UPS shuts down immediately

Battery Low Alarm and Switch Off
Noise Suppression Complies with EN62040-2
Spike Suppression Complies with EN61000-4-5

ALARMS
Audible and Visual Line Failure, Battery Low, Transfer to Bypass, System Fault Condition

PHYSICAL

Dimensions 􀁑 x H x D) UPS Module Rack Configuration 440 x 220 (SU) x 720
Dimensions (;Iv x H x D) Battery Module Rack Configuration 440 X 132 {3U) X 680

Net Weight – kgs -42kg (UPS), -70kg (Battery)

Input & Output Connection Hardwire

ENVIRONMENT
Operating Temperature o c – 40°c
Temperature Warning he battery design life is based on a temperature of 25°C. Ambient temperature above this range will reduce battery life

Altitude 0-2000m up to 40°C, 3000m up to 35°C
Humidity 0 to 95% RH maximum, Non-Condensing
Noise <50dB (at 1 meter)

COMPUTER INTERFACE
Interface Type Standard RS.232 Interface & EPO
Communication Slots 2nd RS232 .. , USB”, RS485 .. , Dry Contact Relay”, SNMP/WEB Card .. , etc. (Optional)

SAFETY CONFORMANCE
Quality Assurance 1S09001 Certified Company
Safety Standard EN62040-1, UL 1778
EMC Standard EN61000..S-2, EN62040-2, EN61000-4, EN61000-2, FCC Class A
Marks CE, UL

Specifications subject to change without prior notice.